Iron Studies report format

( with interpretation )

Iron Studies is a group of blood tests that evaluate the levels of iron in the body and its ability to store and transport iron. These tests typically include Serum Iron, Total Iron-Binding Capacity (TIBC), Ferritin, and Transferrin Saturation. Serum Iron measures the amount of iron in the blood, TIBC reflects the blood's capacity to bind iron, Ferritin indicates stored iron levels, and Transferrin Saturation represents the percentage of transferrin (a protein that transports iron) that is saturated with iron. Iron studies are crucial for diagnosing and managing conditions like iron deficiency anemia, hemochromatosis, and other iron metabolism disorders.

Download word format

Tests included in Iron Studies report:

  • Iron
  • UIBC
  • Total Iron Binding Capacity (TIBC)
  • Transferrin Saturation

Iron Studies Interpretation

In Labsmart software, this is the inbuilt interpretation for Iron Studies

Physiological basis
Plasma iron concentration is determined by absorption from the intestine; storage in the intestine, liver, spleen, bone marrow, rate of breakdown or loss of hemoglobin, and rate of synthesis of new hemoglobin.

Interpretation for Iron (Fe), serum or plasma

Increased Decreased
Hemosiderosis (eg, multiple transfusions, excess iron administration), acute Fe poisoning (children), hemolytic anemia, pernicious anemia, aplastic or hypoplastic anemia, viral hepatitis, lead poisoning, thalassemia, hemochromatosis. Drugs: estrogens, ethanol, oral contraceptives. Iron deficiency, nephrotic syndrome, chronic renal failure, many infections, active hematopoiesis, remission of pernicious anemia, hypothyroidism, malignancy (carcinoma), postoperative state, kwashiorkor.

TIBC correlates with serum transferrin, but the relationship is not linear over a wide range of transferrin values and is disrupted in diseases affecting transferrin-binding capacity or other iron-binding proteins.
Increased in: Iron deficiency anemia, late pregnancy, infancy, acute hepatitis. Drugs: oral contraceptives.
Decreased in: Hypoproteinemic states (eg, nephrotic syndrome, starvation, malnutrition, cancer), hemochromatosis, thalassemia, hyperthyroidism, chronic infections, chronic inflammatory disorders, chronic liver disease, and other chronic diseases.

Increased % transferrin saturation with iron is seen in iron overload (iron poisoning, hemolytic anemia, sideroblastic anemia, thalassemia, hemochromatosis, pyridoxine deficiency, aplastic anemia, RBC transfusions).
Decreased % transferrin saturation with iron is seen in iron deficiency (usually saturation < 16%). It can also be used to assess nutritional status.

All inbuilt interpretations in the Labsmart pathology software is made in consultation with a doctor and is © copyright of Labsmart Healthcare Technologies.

Importance of adding interpretation to reports:

It's very helpful to add interpretation in reports as it makes the reports more patient friendly and also helpful to doctors in some cases. Moreover, presently most labs prefer providing reports with interpretation. Thus, adding interpretation to report will help your lab stay at par with other competitor labs.

Labsmart software

(With Interpretation and auto calculations)

  • Billing
  • Reports with Interpretation
  • Auto calculation where needed
  • Check daily business
  • WhatsApp reports

* Free plan available

Iron Studies Report Format

1.5 Crore+

Reports printed & delivered online

1250+

Labs Active

10+

Countries

Iron Studies MS Word format

(NO interpretation)

Download the Ms word editable Iron Studies report format for offline reporting.

Download word format
Iron Studies word sample image

Anatomy of Labsmart Report

Anatomy of Labsmart Lab Report

What our customer says about us

We have been using Labsmart since 2 years, and it's been a pleasant experience. The software is user-friendly, continuously improving with each update. The team behind it is incredibly helpful, addressing any issues promptly. Abhishek, the founder and developer, is a nice person who patiently listens and does what's best. Deepa in customer support does a great job. Thanks to the Labsmart team for their excellent work!
Dr. Pritam

Dr. Priyatamjee Bussary

verified reviews
Labsmart pathalogy software is a very good platform. I have been using this software after using multiple pathalogy software’s many of them are costly and difficult to understand but Labsmart software is very easy to understand, it's sms feature , sharing pdf and storing database of patients are the best functions of the software. It is a very cost-friendly and less complicated than other software.
Mr. Ankit Dubey

Ankit kumar Dube

verified reviews
Wonderful software, Labsmart has very good and knowledgeable technical staff who assisted me greatly in setting up my software and answering all of my questions. My work load has decreased significantly since I began using the Labsmart software.
Dhar Pathological Laboratory owner/manager

Dhar pathological laboratory

verified reviews
Chat with us on WhatsApp